Rotary table ACR-490HT (High torque)

Rotary table ACR-490HT (High torque)
Click to enlarge

Diameter 675 mm

Aperture 490 mm

Height 68 mm


 

AccuRing rotary tables provide superior angular positioning and are designed to eliminate backlash, friction and wear problems associated with worm, gear and belt drives. Low maintenance and high throughput characteristics of the AccuRing stage yields the lowest total cost of ownership.

 

Compact package and Superior design of the AccuRing rotary stages was optimized to minimize stage height. The low profile of the stage reduces total system working height. Angular contact bearings are used to maximize performance with respect to wobble, moment stiffness and friction. AccuRing stage has large clear center aperture that can be used for air or wire line feed-through or beam delivery.

 

AccuRing utilizes direct drive three phase brushless motor technology. There are no brushes to replace and no gear trains or belts to maintain. Coreless magnetic design assures smooth rotation and dynamic performance.

 

Accurate Positioning is assured with contact-less encoder. The motor and rotary encoders are directly coupled to eliminate coupling backlash. The low inertia and zero backlash make AccuRing the ideal solution for applications requiring frequent directional changes.

 

 

Semiconductor assembly

    Electronics assembly

Precision machine tools

    Robotic handlers

Wafer processing

    Automation

 

 
System Performance

Unit

ACR-490HT

Center aperture

mm

490

Outside diameter

mm

675

Stage height

mm

68

Peak Torque

Tp

 (Nm)

650

Continuous torque

air cooling, coil 120°C

Tc120

(Nm)

335

Peak current at Tp

Amp p rrms

12-22

Continuous current at Tc

Amp c rrms

5-8

Supply voltage (note 1)

Uvac

220-380

Max speed at Tp and Us  

(note 2)

RPM

66

Max speed at Tc and Us  

(note 2)

RPM

100

Positioning resolution

(note 3)

counts/rev

 

1,656,000 - 6,624,000

Positioning resolution

(arc-sec)

0.2-0.78

Accuracy

Arc-sec

<30

Repeatability Arc-sec <1

Run-out axial/radial

micron

<30

Rotor Inertia kr x m2 0.5

Stage weight

M (Kg)

65

Load weight

M (Kg)

500

 

Note 1: Rotary table can operate at lower voltages with lower speeds

Note 2: Speed values shown at rated torque

Note 3: Max speed may be limited by controller's encoder frequency input.

            Sin/cos 1 Vpp and other encoder resolutions available.

            Contact the factory.

There are no ordering details for this product.